Powder Containment Booth

Construction

Code Compliance

NFPA 33 Standard for Spray Application Using Flammable or Combustible Materials
NFPA 34 Standard for Dipping, Coating, and Printing Processes Using Flammable or Combustible Liquids
NFPA 70 National Electric Code
NFPA 91 Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Particulate Solids
NFPA 101 Life Safety code
IBC International Building Code
UMC Uniform Mechanical Code
IFC International Fire Code
*Electrical components, such as motors, motor starters, disconnect switches, push buttons, and lights are listed or approved for the Class and Division in which they are located.

Booth Package

  • Fan & Motor
  • Exhaust Filters
  • Solenoid Valve
  • Nuts & Bolts
  • Manometer
  • Light Fixtures
  • Assembly Instructions
  • Door interlock hardware – Brixon Latches (for filtered door booths) 
  • Tubes or Bulbs
  • Duct Package
  • Sprinkler Systems
  • Air Lines
  • Electrical Switches
  • Motor Starter
  • Attachment Anchors from booth to floor
  • Electrical Hookup
  • Conveyor Openings
  • Explosion-Proof Motors
  • Custom Sizing
  • Powder coating of panels

NOTES: 

POWDER CONTAINMENT BOOTHS are used for spraying powder and/or grinding non-metallic (fiberglass, etc,) items. This equipment is for low volume usage. Exhaust air can be recirculated back into the factory, thereby eliminating the need for roof penetration and/or air replacement. Because of environmental restrictions, this type of booth has become a very popular alternative to inexpensively enter into the powder coating industry 

1

LIGHT FIXTURES 

U.L. and C-U.L. approved. 120-volt Light Fixtures. Fluorescent and LED available
Types
  • Vapor- Tight (V.T.) for Class 1, Division 2 locations (National Electric Code and NFPA 70) 
  • Listed Open-Type (O.T.) fixtures 
Mounting
  • Placed on the outside of ¼” clear tempered (heat treated) glass, gasketed and locked into place at the working depth.
2

FAN

Construction
  • Construction for fan is of non-sparking materials.
  • AMCA Certified for air and sound
  • Fabricated Aluminum Blades
Motor
  • Motors are U.L. Listed
  • 3-phase, 208/230/460 volt, 60Hz
  • Face Velocity exceeds 100 F.P.M. code requirement
  • See specs for C.F.M. values per booth size
  • Belt driven with enclosed belt guards
  • Motor to include identification plate stating the ventilation rate for which the system is designed
3

FINAL FILTERS

4

FINAL FILTER BOX

5

MANOMETER 

A visual differential pressure gauge required for filtered spray booths. As build-up occurs, pressure increasesThe manometer provides a visual indication that filter(s) require replacement. 

6

MANOMETER 

A visual differential pressure gauge required for filtered spray booths. As build-up occurs, pressure increasesThe manometer provides a visual indication that filter(s) require replacement. 
SKUWIDTH I.D.HEIGHT I.D.WORKING DEPTHPLENUM DEPTHUPPER PLENUMFILTER CELLSFINAL FILTERSFLUOR. LIGHTS NO. & TYPEWIDTH OVERALLHEIGHT OVERALLDEPTH OVERALLEXHAUST FANMOTOR H.P.C.F.M. @ 1/4" S.P. AVERAGE
C-4-7-74'-0"6'-10"7'-0"2'-0"3'-7"821-VT-FLUR4'-4"7'-4"9'-2"1-18"1-1/23,800
C-4-8-74'-0"7'-10"7'-0"2'-0"3'-7"821-VT-FLUR4'-4"8'-4"9'-2"1-18"1-1/23,800
C-5-7-75'-0"6'-10"7'-0"2'-6"3'-8"1241-VT-FLUR5'-4"7'-4"9'-8"1-24"26,490
C-5-8-75'-0"7'-10"7'-0"2'-6"3'-8"1241-VT-FLUR5'-4"8'-4"9'-8"1-24"26,490
C-6-7-76'-0"6'-10"7'-0"2'-6"3'-8"1241-VT-FLUR6'-4"7'-4"9'-8"1-24"26,490
C-6-8-76'-0"7'-10"7'-0"2'-6"3'-8"1241-VT-FLUR6'-4"8'-4"9'-8"1-24"26,490
C-8-7-78'-0"6'-10"7'-0"2'-6"3'-8"1641-VT-FLUR8'-4"7'-4"9'-8"1-24"26,490
C-8-8-78'-0"7'-10"7'-0"3'-0"4'-2"1661-VT-FLUR8'-4"8'-4"10'-2"1-30"39,740
C-10-7-710'-0"6'-10"7'-0"3'-0"4'-2"2062-VT-FLUR10'-4"7'-4"10'-2"1-30"39,740
C-10-8-710'-0"7'-10"7'-0"3'-0"4'-2"2062-VT-FLUR10'-4"8'-4"10'-2"1-30"39,740
C-10-10-710'-0"9'-10"7'-0"3'-6"5'-5"2582-VT-FLUR10'-4"10'-4"10'-8"1-34"514,445
C-10-12-710'-0"11'-10"7'-0"3'-6"5'-5"3082-VT-FLUR10'-4"12'-4"10'-8"1-34"514,445
C-12-7-712'-0"6'-10"7'-0"3'-6"5'-5"2882-VT-FLUR12'-4"7'-4"10'-8"1-34"514,445
C-12-8-712'-0"7'-10"7'-0"3'-6"5'-5"2882-VT-FLUR12'-4"8'-4"10'-8"1-34"514,445
C-12-10-712'-0"9'-10"7'-0"3'-6"5'-5"3583-VT-FLUR12'-4"10'-4"10'-8"1-34"514,445
C-12-12-712'-0"11'-10"7'-0"4'-0"5'-8"42123-VT-FLUR12'-4"12'-4"11'-2"1-42"7-1/221,775
C-14-7-1014'-0"6'-10"10'-0"3'-6"5'-5"3284-OT-FLUR15'-0"7'-6"13'-8"1-34"514,445
C-14-8-1014'-0"7'-10"10'-0"3'-6"5'-5"3284-OT-FLUR15'-0"8'-6"13'-8"1-34"514,445
C-14-10-1014'-0"9'-10"10'-0"4'-0"5'-8"40124-OT-FLUR15'-0"10'-6"14'-2"1-42"7-1/221,775
C-14-12-1014'-0"11'-10"10'-0"4'-0"5'-8"48124-OT-FLUR15'-0"12'-6"14'-2"1-42"7-1/221,775
C-16-7-1016'-0"6'-10"10'-0"3'-6"5'-5"3683-OT-FLUR17'-0"7'-6"13'-8"1-34"514,445
C-16-8-1016'-0"7'-10"10'-0"3'-6"5'-5"3684-OT-FLUR17'-0"8'-6"13'-8"1-34"514,445
C-16-10-1016'-0"9'-10"10'-0"3'-0"4'-2"45125-OT-FLUR17'-0"10'-6"13'-2"2-30"2-319,480
C-16-12-1016'-0"11'-10"10'-0"3'-6"5'-5"54165-OT-FLUR17'-0"12'-6"13'-8"2-34"2-528,890
C-18-7-1018'-0"6'-10"10'-0"3'-6"5'-5"4084-OT-FLUR19'-0"7'-6"13'-8"1-36"514,825
C-18-8-1018'-0"7'-10"10'-0"3'-0"4'-2"40124-OT-FLUR19'-0"8'-6"13'-2"2-30"2-319,480
C-18-10-1018'-0"9'-10"10'-0"3'-6"5'-5"50165-OT-FLUR19'-0"10'-6"13'-8"2-34"2-529,890
C-18-12-1018'-0"11'-10"10'-0"3'-6"5'-5"60165-OT-FLUR19'-0"12'-6"13'-8"2-34"2-528,890
C-20-7-1020'-0"6'-10"10'-0"3'-0"4'-2"44125-OT-FLUR21'-0"7'-6"13'-2"2-30"2-319,480
C-20-8-1020'-0"7'-10"10'-0"3'-0"4'-2"44125-OT-FLUR21'-0"8'-6"13'-2"2-30"2-319,480
C-20-10-1020'-0"9'-10"10'-0"3'-6"5'-5"55166-OT-FLUR21'-0"10'-6"13'-8"2-34"2-528,890
C-20-12-1020'-0"11'-10"10'-0"3'-6"5'-5"66166-OT-FLUR21'-0"12'-6"13'-8"2-34"2-528,890
SKUWIDTH I.D.HEIGHT I.D.WORKING DEPTHPLENUM DEPTHUPPER PLENUMFILTER CELLSFINAL FILTERSFLUOR. LIGHTS NO. & TYPEWIDTH OVERALLHEIGHT OVERALLDEPTH OVERALLEXHAUST FANMOTOR H.P.C.F.M. @ 1/4" S.P. AVERAGE

Request a Quote or Custom Build